home *** CD-ROM | disk | FTP | other *** search
/ Spec Disk 1998 Spring 4.0 / Spec Disk 1998 Spring 4.0.iso / text / 07723avi.txt < prev    next >
Text File  |  1998-06-10  |  13KB  |  347 lines

  1.                          SECTION 07723
  2.  
  3.                   RIDGE VENTS AND SOFFIT VENTS
  4. NOTE ** This section is based on products manufactured by
  5.         Air Vent Inc., A CertainTeed Company, at the
  6.         following address:
  7. NOTE **    3000 West Commerce Street
  8. NOTE **    Dallas TX 75212
  9. NOTE **    Tel: (800) AIR-VENT
  10. NOTE **    Fax: (800) 635-7006
  11. NOTE **
  12. NOTE ** Air Vent Inc. manufactures roof vents, soffit
  13.         vents, and foundation vents in aluminum and PVC.
  14. NOTE **
  15. NOTE ** SECTION 07723 - RIDGE VENTS AND SOFFIT VENTS,
  16.         Copyright 1997, The Architect's Catalog, Inc.
  17.  
  18. PART 1  GENERAL
  19.  
  20. 1.1 SECTION INCLUDES
  21. NOTE ** Delete items below not required for project.
  22.  
  23.     A.  Ridge vents for wood frame structures.
  24.  
  25.     B.  Soffit vents for wood frame structures.
  26.  
  27. 1.2 RELATED SECTIONS
  28. NOTE ** Delete any sections below not relevant to this
  29.         project; add others as required.
  30.  
  31.     A.  Section 06100 - Rough Carpentry.
  32.  
  33.     B.  Section 07310 - Shingles.
  34.  
  35.     C.  Section 07320 - Roof Tiles.
  36.  
  37. 1.3 REFERENCES
  38.  
  39.     A.  AMCA 210 - Laboratory Methods of Testing Fans for Rating;
  40.         Air Movement and Control Association International, Inc.
  41.         (also listed under the designation ASHRAE 51 - Laboratory
  42.         Methods of Testing Fans for Rating; American Society of
  43.         Heating, Refrigerating, and Air Conditioning Engineers,
  44.         Inc.)
  45.  
  46. 1.4 SYSTEM DESCRIPTION
  47.  
  48.     A.  Provide vents that comply with requirements of the
  49.         following:
  50. NOTE ** Delete any of the following sub-paragraphs
  51.         containing code requirements not applicable to
  52.         project jurisdiction.
  53.         1.  FHA Minimum Property Standards.
  54.         2.  Published recommendations of the US Department of
  55.             Housing and Urban Development.
  56. NOTE ** The following sub-paragraph should be retained,
  57.         since Dade County has reputedly one of the most
  58.         stringent building codes in the USA.
  59.         3.  1995 building requirements of Dade County, Florida.
  60.         4.  BOCA.
  61.         5.  SBCCI.
  62.         6.  ICBO.
  63.         7.  Canadian Standards Association.
  64. NOTE ** Delete the following two paragraphs if not
  65.         specifying ridge vents.
  66.  
  67.     B.  Provide ridge vents with external wind baffle to create
  68.         negative air pressure that pulls air out of attic and
  69.         helps prevent clogging of vent slots, and deflect weather
  70.         and debris from entering attic space; provide ridge vents
  71.         with internal weather filter to help form complete
  72.         barrier against wind-blown rain, snow, dust, or insects.
  73.  
  74.     C.  Ridge vents, when tested under 15 miles-per-hour (24
  75.         k/hr) wind condition, to exhibit the following
  76.         performance characteristics:
  77. NOTE ** Airflow out of attic indicates passive attic
  78.         ventilation, and helps prevent snow, rain, dust, or
  79.         insects from getting into the attic space and from
  80.         clogging vent slots.
  81. NOTE **
  82. NOTE ** Delete one of the following two sub-paragraphs;
  83.         first is for FilterVent units, second is for
  84.         ShingleVent units.
  85.         1.  Airflow out of attic, tested in airflow chamber
  86.             designed in accordance with AMCA 210:  100 cubic feet
  87.             per minute (168 cu m/hr) for 4-foot (1220 mm)
  88.             section, minimum.
  89.         2.  Airflow out of attic, tested in airflow chamber
  90.             designed in accordance with AMCA 210:  70 cubic feet
  91.             per minute (109.2 cu m/hr) for 4-foot (1220 mm)
  92.             section, minimum.
  93.  
  94. 1.5 SUBMITTALS
  95.  
  96.     A.  Submit under provisions of Section 01300.
  97.  
  98.     B.  Product Data:  Manufacturer's technical literature,
  99.         specifications and installation instructions.
  100.  
  101.     C.  Shop Drawings:  Show layout of vents, rough-in
  102.         requirements, and details of attachment to substrates.
  103.  
  104.     D.  Test reports:  Submit certified reports from independent
  105.         testing laboratory documenting compliance with
  106.         performance requirements specified in SYSTEM DESCRIPTION
  107.         Article of this section.
  108.  
  109. 1.6 WARRANTY
  110.  
  111.     A.  Manufacturer to warrant ridge vents against defects in
  112.         materials for a period of 30 years from the date of
  113.         Substantial Completion, transferable from original owner
  114.         to new owner; warranty to include, for the first five
  115.         years of warranty period, reimbursement for labor costs
  116.         incurred in removing defective vent and installing vent
  117.         replacement, in addition to the replacement product
  118.         itself.
  119.  
  120. PART 2  PRODUCTS
  121.  
  122. 2.1 MANUFACTURERS
  123.  
  124.     A.  Acceptable Manufacturer:  Air Vent Inc., A CertainTeed
  125.         Company, 3000 West Commerce Street, Dallas, TX 75212.
  126.         ASD. Tel: (800) AIR-VENT. Fax: (800) 635-7006.
  127. NOTE ** Delete one of the two following paragraphs;
  128.         coordinate with Division 1 requirements.
  129.  
  130.     B.  Requests for substitutions will be considered in
  131.         accordance with provisions of Section 01600.
  132.  
  133.     C.  Substitutions:  Not permitted.
  134.  
  135. 2.2 PRODUCTS
  136. NOTE ** Refer to Air Vent catalog for selection of required
  137.         exhaust vents.  Select color for each item retained
  138.         or retain the sub-paragraph containing "Selected by
  139.         Architect from manufacturer's range of standard
  140.         colors."
  141.  
  142.     A.  Shingle-Over Ridge Vent:
  143.         1.  Acceptable product:  ShingleVent II, size 12 inches
  144.             wide, Model SHFV203.
  145.         2.  Net free area:  18 square inches per linear foot (3.5
  146.             sq m/lin m).
  147.         3.  Color:  Black.
  148.         4.  Color:  Brown.
  149.         5.  Color:  Gray.
  150.         6.  Color:  Charcoal.
  151.         7.  Color:  Selected by Architect from manufacturer's
  152.             standard colors.
  153.  
  154.     B.  Shingle-Over Ridge Vent:
  155.         1.  Acceptable product:  ShingleVent II-9, size 9 inches
  156.             wide, Model SHFV209.
  157.         2.  Net free area:  18 square inches per linear foot (3.5
  158.             sq m/lin m).
  159.         3.  Color:  Charcoal.
  160.  
  161.     C.  Shingle-Over Ridge Vent:
  162.         1.  Acceptable product:  ShingleVent II-7, size 7 inches
  163.             wide, Model SHFVII-7.
  164.         2.  Net free area:  18 square inches per linear foot (3.5
  165.             sq m/lin m).
  166.         3.  Color:  Charcoal.
  167.  
  168.     D.  Aluminum Ridge Vent:
  169.         1.  Acceptable product:  Multi-Pitch FilterVent, Model
  170.             FV101, 10-foot length.
  171.         2.  Net free area:  18 square inches per linear foot (3.5
  172.             sq m/lin m).
  173.         3.  Color:  Black.
  174.         4.  Color:  Brown.
  175.         5.  Color:  White.
  176.         6.  Color:  Gray.
  177.         7.  Color:  Mill.
  178.         8.  Color:  Bronze.
  179.         9.  Color:  Zinc.
  180.         10. Color:  Copper.
  181.         11. Color:  Selected by Architect from manufacturer's
  182.             standard colors.
  183.  
  184.     E.  Aluminum Ridge Vent:
  185.         1.  Acceptable product:  Multi-Pitch FilterVent, Model
  186.             FV110, 8-foot length.
  187.         2.  Net free area:  18 square inches per linear foot (3.5
  188.             sq m/lin m).
  189.         3.  Color:  Black.
  190.         4.  Color:  Brown.
  191.         5.  Color:  White.
  192.         6.  Color:  Gray.
  193.         7.  Color:  Mill.
  194.         8.  Color:  Bronze.
  195.         9.  Color:  Zinc.
  196.         10. Color:  Copper.
  197.         11. Color:  Selected by Architect from manufacturer's
  198.             standard colors.
  199.  
  200.     F.  Aluminum Peak Vent:
  201.         1.  Acceptable product:  Peak FilterVent, Model PVF152, 8-
  202.             foot length.
  203.         2.  Net free area:  9 square inches per linear foot (1.7
  204.             sq m/lin m).
  205.         3.  Color:  Black.
  206.         4.  Color:  Brown.
  207.         5.  Color:  Gray.
  208.         6.  Color:  Bronze.
  209.         7.  Color:  Selected by Architect from manufacturer's
  210.             standard colors.
  211.  
  212.     G.  Aluminum Vent for Roof/Wall Junctions:
  213.         1.  Acceptable product:  Flash FilterVent, Model FFV162,
  214.             8-foot length.
  215.         2.  Net free area:  9 square inches per linear foot (1.7
  216.             sq m/lin m).
  217.         3.  Color:  Black.
  218.         4.  Color:  Brown.
  219.         5.  Color:  Gray.
  220.         6.  Color:  Bronze.
  221.         7.  Color:  Copper.
  222.         8.  Color:  Selected by Architect from manufacturer's
  223.             standard colors.
  224.  
  225.     H.  Adaptor Cover:
  226.         1.  Acceptable product:  Tile/Shake FilterVent, Model
  227.             TFV111.
  228.         2.  Net free area:  18 square inches per linear foot (3.5
  229.             sq m/lin m).
  230.         3.  Color:  Black.
  231.         4.  Color:  Brown.
  232.         5.  Color:  White.
  233.         6.  Color:  Gray.
  234.         7.  Color:  Mill.
  235.         8.  Color:  Selected by Architect from manufacturer's
  236.             standard colors.
  237. NOTE ** Retain the following paragraph if specifying for
  238.         retrofit installation.
  239.  
  240.     I.  Aluminum Continuous Soffit Vent:
  241.         1.  Acceptable product:  Continuous Soffit Vent Model
  242.             SV201.
  243.         2.  Net free area:  9 square inches per linear foot (1.7
  244.             sq m/lin m).
  245.         3.  Color:  White.
  246.         4.  Color:  Mill.
  247.         5.  Color:  Brown.
  248.         6.  Color:  Selected by Architect from manufacturer's
  249.             standard colors.
  250. NOTE ** Retain the following paragraph if specifying for
  251.         new construction.
  252.  
  253.     J.  Aluminum Continuous Soffit Vent:
  254.         1.  Acceptable product:  Continuous Soffit Vent Model
  255.             SV202.
  256.         2.  Net free area:  9 square inches per linear foot (1.7
  257.             sq m/lin m).
  258.         3.  Color:  White.
  259.         4.  Color:  Mill.
  260.         5.  Color:  Brown.
  261.         6.  Color:  Selected by Architect from manufacturer's
  262.             standard colors.
  263. NOTE ** Retain the following paragraph if specifying for
  264.         retrofit installation.
  265.  
  266.     K.  PVC Continuous Soffit Vent:
  267.         1.  Acceptable product:  Continuous Soffit Vent Model
  268.             SV351.
  269.         2.  Net free area:  9 square inches per linear foot (1.7
  270.             sq m/lin m).
  271.         3.  Color:  White.
  272.         4.  Color:  Brown.
  273.         5.  Color:  Selected by Architect from manufacturer's
  274.             standard colors.
  275. NOTE ** Retain the following paragraph if specifying for
  276.         new construction.
  277.  
  278.     L.  PVC Continuous Soffit Vent:
  279.         1.  Acceptable product:  Strip Vent Model SV352.
  280.         2.  Net free area:  9 square inches per linear foot (1.7
  281.             sq m/lin m).
  282.         3.  Color:  White.
  283.         4.  Color:  Brown.
  284.         5.  Color:  Selected by Architect from manufacturer's
  285.             standard colors.
  286.  
  287.     M.  Aluminum Eave Vent:
  288.         1.  Acceptable product:  Undereave Vent Model EV16424,
  289.             size 4 inches (101 mm) wide by 16 inches (406 mm)
  290.             long.
  291.         2.  Net free area:  28 square inches (0.018 sq m) per
  292.             unit.
  293.         3.  Color:  White.
  294.         4.  Color:  Mill.
  295.         5.  Color:  Brown.
  296.         6.  Color:  Selected by Architect from manufacturer's
  297.             standard colors.
  298.  
  299.     N.  Aluminum Eave Vent:
  300.         1.  Acceptable product:  Undereave Vent Model EV16624,
  301.             size 6 inches (152 mm) wide by 16 inches (406 mm)
  302.             long.
  303.         2.  Net free area:  42 square inches per unit (0.027 sq
  304.             m).
  305.         3.  Color:  White.
  306.         4.  Color:  Mill.
  307.         5.  Color:  Brown.
  308.         6.  Color:  Selected by Architect from manufacturer's
  309.             standard colors.
  310.  
  311.     O.  Aluminum Eave Vent:
  312.         1.  Acceptable product:  Undereave Vent Model EV16812,
  313.             size 8 inches (203 mm) wide by 16 inches (406 mm)
  314.             long.
  315.         2.  Net free area:  56 square inches (0.036 sq m) per
  316.             unit.
  317.         3.  Color:  White.
  318.         4.  Color:  Mill.
  319.         5.  Color:  Brown.
  320.         6.  Color:  Selected by Architect from manufacturer's
  321.             standard colors.
  322.  
  323.     P.  Aluminum Drip Edge Vent:
  324.         1.  Acceptable product:  Drip Edge Vent Model DEV141.
  325.         2.  Net free area:  9 square inches per linear foot (1.7
  326.             sq m/lin m).
  327.         3.  Color:  White.
  328.         4.  Color:  Mill.
  329.         5.  Color:  Brown.
  330.         6.  Color:  Black.
  331.         7.  Color:  Selected by Architect from manufacturer's
  332.             standard colors.
  333.  
  334. PART 3  EXECUTION
  335.  
  336. 3.1 EXAMINATION
  337.  
  338.     A.  Verification of Conditions:  Verify that framing,
  339.         substrate, and finish materials have been installed.
  340.  
  341. 3.2 INSTALLATION
  342.  
  343.     A.  Install vents in accordance with manufacturer's printed
  344.         instructions.
  345.  
  346.                          END OF SECTION
  347.